1.For each read we need one CAS and one RAS.
|
|
2.Once data is present, CAS & RAS must be
turned off.
|
|
3.CAS & RAS must recover (precharge) before
the next read.
|
|
4.Latency is sum of Access time and cycle time.
|
|
5.Access time is from Row Address signal to Data
out.
|
|
6.Cycle time is recovery time. I.e. RAS precharge.
|
|
|
|
1. CAS for Col 2 can not start until Data 1